Modellbiblioteket openEHR Fork
Name
Refraction Details
Description
Details of ocular refraction for both measurement and therapetic purposes.
Keywords
eye correction
Purpose
To record details of ocular refraction applied either as part of visual acuity testing, to report a subject's current correction of spectacles or contact lenses, or to request a new ocular prescription.
Use
This archetype is normally used within the OBSERVATION.visual_acuity archetype to record a refraction applied as part of measurement or within INSTRUCTION and ACTION archetypes where a prescription order and supply process is being modelled.
References
IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf
Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583&sectionTitle=Cataract+National+Data+Set+for+Adults
CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/
DICOM Supplement 30 [Internet]. [cited 2012 Sep 26]. Available from: http://medical.nema.org/
Archetype Id
openEHR-EHR-CLUSTER.refraction_details.v0
Copyright
© openEHR Foundation
Licencing
This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/.
Original Author
Gustavo M Bacelar-Silva
Date Originally Authored
To record details of ocular refraction applied either as part of visual acuity testing, to report a subject's current correction of spectacles or contact lenses, or to request a new ocular prescription.
Language Details
Norwegian Bokmal
Thomas Baerland
Oslo Universitetssykehus HF / DIPS ASA
Portuguese (Brazil)
Gustavo Bacelar-Silva
Healthcare Designs
Name Card Type Description
Power of Sphere
0..1 DV_QUANTITY Correction of the sphere, the base correction upon which cylinder, reading addition and prism may be superimposed.
DV_QUANTITY
Power of Cylinder
0..1 DV_QUANTITY Correction of the cylinder.
DV_QUANTITY
Axis of Cylinder
0..1 DV_QUANTITY Correction of the axis.
DV_QUANTITY
Prism Strength
0..1 DV_QUANTITY Strength of the prism.
DV_QUANTITY
Prism Base Direction
0..1
CHOICE OF
DV_CODED_TEXT
DV_QUANTITY
Prism base direction expressed as a numeric angle or as coded text.
Constraint for DV_CODED_TEXT
  • Base in
    [The prism base is directed inwards.]
  • Base out
    [The prism base is directed outwards.]
  • Base up
    [The prism base is directed upwards.]
  • Base down
    [The prism base is directed downwards.]
  • Base oblique
    [The prism base is directed obliquely.]
DV_QUANTITY
Reading Addition Power
0..1 DV_QUANTITY The difference in spherical power between distance and near corrections.
DV_QUANTITY
Intermediate Distance Power
0..1 DV_QUANTITY The intermediate distance power applied to the correction.
DV_QUANTITY
Interpupillary Distance
0..1 DV_QUANTITY The distance between the center of the pupils of the two eyes.
DV_QUANTITY
archetype (adl_version=1.4; uid=db395587-546b-48c3-84c1-384f990cc222)
	openEHR-EHR-CLUSTER.refraction_details.v0

concept
	[at0000]	-- Refraction Details
language
	original_language = <[ISO_639-1::en]>
	translations = <
		["nb"] = <
			language = <[ISO_639-1::nb]>
			author = <
				["name"] = <"Thomas Baerland">
				["organisation"] = <"Oslo Universitetssykehus HF / DIPS ASA">
				["email"] = <"tba@dips.no">
			>
			accreditation = <"?">
		>
		["pt-br"] = <
			language = <[ISO_639-1::pt-br]>
			author = <
				["name"] = <"Gustavo Bacelar-Silva">
				["organisation"] = <"Healthcare Designs">
			>
		>
	>
description
	original_author = <
		["name"] = <"Gustavo M Bacelar-Silva">
		["email"] = <"mail@gustavobacelar.com">
		["date"] = <"2012-09-10">
	>
	details = <
		["nb"] = <
			language = <[ISO_639-1::nb]>
			purpose = <"Formål å registrere okulær refraksjon alene eller som del av visusundersøkelse.">
			use = <"Denne arketypen brukes vanligvis som cluster i OBSERVATION.visual_acuity arketypen for å registrere visus.">
			keywords = <"*øye", "*visus", "*korreksjon", "*refraksjon">
			misuse = <"">
		>
		["pt-br"] = <
			language = <[ISO_639-1::pt-br]>
			purpose = <"Registrar os detalhes da refração ocular durante o teste de acuidade visual, para registrar a correção do paciente obtida durante o exame físico ou para a prescrição de lentes (óculos ou contato).">
			use = <"*This archetype is normally used within the OBSERVATION.visual_acuity archetype to record a refraction applied as part of measurement or within INSTRUCTION and ACTION archetypes where a prescription order and supply process is being modelled.(en)">
			keywords = <"olho", "correção", "refração", "dioptria", "lenses">
			misuse = <"">
			copyright = <"© openEHR Foundation">
		>
		["en"] = <
			language = <[ISO_639-1::en]>
			purpose = <"To record details of ocular refraction applied either as part of visual acuity testing, to report a subject's current correction of spectacles or contact lenses, or to request a new ocular prescription.">
			use = <"This archetype is normally used within the OBSERVATION.visual_acuity archetype to record a refraction applied as part of measurement or within INSTRUCTION and ACTION archetypes where a prescription order and supply process is being modelled.">
			keywords = <"eye", "correction">
			misuse = <"">
			copyright = <"© openEHR Foundation">
		>
	>
	lifecycle_state = <"in_development">
	other_contributors = <"Gustavo Bacelar-Silva, Brazil (Editor)", "Mike Mair, Timaru Eye Clinic, New Zealand", "Ian McNicoll, Ocean Informatics, United Kingdom (Editor)">
	other_details = <
		["licence"] = <"This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/.">
		["custodian_organisation"] = <"openEHR Foundation">
		["references"] = <"IHE Eye Care Domain. General Eye Evaluation (GEE) [Internet]. IHE; 2012. Available from: http://www.ihe.net/Technical_Framework/upload/IHE_EyeCare_Supp_GEE_Rev1-1_TI_2012-06-29.pdf

Royal College of Opthalmologists. Cataract National Dataset for Adults [Internet]. 2011. Available from: http://www.rcophth.ac.uk/page.asp?section=583§ionTitle=Cataract+National+Data+Set+for+Adults

CfH, UK. Do Once & Share - Glaucoma [Internet]. [cited 2012 Sep 26]. Available from: http://www.doasglaucoma.org/

DICOM Supplement 30 [Internet]. [cited 2012 Sep 26]. Available from: http://medical.nema.org/">
		["current_contact"] = <"Gustavo M Bacelar-Silva, mail@gustavobacelar.com">
		["original_namespace"] = <"org.openehr">
		["original_publisher"] = <"openEHR Foundation">
		["custodian_namespace"] = <"org.openehr">
		["MD5-CAM-1.0.1"] = <"7AEF92C688CD13F85B78F9C263160847">
		["build_uid"] = <"1ff298a7-9698-40ba-a272-61784df6d0f4">
		["revision"] = <"0.0.1-alpha">
	>

definition
	CLUSTER[at0000] matches {	-- Refraction Details
		items cardinality matches {1..*; unordered} matches {
			ELEMENT[at0004] occurrences matches {0..1} matches {	-- Power of Sphere
				value matches {
					C_DV_QUANTITY <
						property = <[openehr::685]>
						list = <
							["1"] = <
								units = <"dioptre">
								magnitude = <|-100.0..100.0|>
								precision = <|2|>
							>
						>
					>
				}
			}
			ELEMENT[at0005] occurrences matches {0..1} matches {	-- Power of Cylinder
				value matches {
					C_DV_QUANTITY <
						property = <[openehr::685]>
						list = <
							["1"] = <
								units = <"dioptre">
								magnitude = <|-100.0..100.0|>
								precision = <|2|>
							>
						>
					>
				}
			}
			ELEMENT[at0006] occurrences matches {0..1} matches {	-- Axis of Cylinder
				value matches {
					C_DV_QUANTITY <
						property = <[openehr::497]>
						list = <
							["1"] = <
								units = <"°">
								magnitude = <|0.0..180.0|>
								precision = <|1|>
							>
						>
					>
				}
			}
			ELEMENT[at0007] occurrences matches {0..1} matches {	-- Prism Strength
				value matches {
					C_DV_QUANTITY <
						property = <[openehr::685]>
						list = <
							["1"] = <
								units = <"dioptre">
							>
						>
					>
				}
			}
			ELEMENT[at0008] occurrences matches {0..1} matches {	-- Prism Base Direction
				value matches {
					DV_CODED_TEXT matches {
						defining_code matches {
							[local::
							at0009, 	-- Base in
							at0010, 	-- Base out
							at0011, 	-- Base up
							at0012, 	-- Base down
							at0013]	-- Base oblique
						}
					}
					C_DV_QUANTITY <
						property = <[openehr::497]>
						list = <
							["1"] = <
								units = <"°">
								magnitude = <|0.0..360.0|>
							>
						>
					>
				}
			}
			ELEMENT[at0014] occurrences matches {0..1} matches {	-- Reading Addition Power
				value matches {
					C_DV_QUANTITY <
						property = <[openehr::685]>
						list = <
							["1"] = <
								units = <"dioptre">
								precision = <|2|>
							>
						>
					>
				}
			}
			ELEMENT[at0015] occurrences matches {0..1} matches {	-- Intermediate Distance Power
				value matches {
					C_DV_QUANTITY <
						property = <[openehr::685]>
						list = <
							["1"] = <
								units = <"dioptre">
								precision = <|2|>
							>
						>
					>
				}
			}
			ELEMENT[at0016] occurrences matches {0..1} matches {	-- Interpupillary Distance
				value matches {
					C_DV_QUANTITY <
						property = <[openehr::122]>
						list = <
							["1"] = <
								units = <"mm">
								magnitude = <|0.0..500.0|>
								precision = <|1|>
							>
						>
					>
				}
			}
		}
	}



ontology
	terminologies_available = <"SNOMED-CT", ...>
	term_definitions = <
		["en"] = <
			items = <
				["at0000"] = <
					text = <"Refraction Details">
					description = <"Details of ocular refraction for both measurement and therapetic purposes.">
				>
				["at0004"] = <
					text = <"Power of Sphere">
					description = <"Correction of the sphere,  the base correction upon which cylinder, reading addition and prism may be superimposed.">
				>
				["at0005"] = <
					text = <"Power of Cylinder">
					description = <"Correction of the cylinder.">
				>
				["at0006"] = <
					text = <"Axis of Cylinder">
					description = <"Correction of the axis.">
				>
				["at0007"] = <
					text = <"Prism Strength">
					description = <"Strength of the prism.">
				>
				["at0008"] = <
					text = <"Prism Base Direction">
					description = <"Prism base direction expressed as a numeric angle or as coded text.">
				>
				["at0009"] = <
					text = <"Base in">
					description = <"The prism base is directed inwards.">
				>
				["at0010"] = <
					text = <"Base out">
					description = <"The prism base is directed outwards.">
				>
				["at0011"] = <
					text = <"Base up">
					description = <"The prism base is directed upwards.">
				>
				["at0012"] = <
					text = <"Base down">
					description = <"The prism base is directed downwards.">
				>
				["at0013"] = <
					text = <"Base oblique">
					description = <"The prism base is directed obliquely.">
				>
				["at0014"] = <
					text = <"Reading Addition Power">
					description = <"The difference in spherical power between distance and near corrections.">
				>
				["at0015"] = <
					text = <"Intermediate Distance Power">
					description = <"The intermediate distance power applied to the correction.">
				>
				["at0016"] = <
					text = <"Interpupillary Distance">
					description = <"The distance between the center of the pupils of the two eyes.">
				>
			>
		>
		["pt-br"] = <
			items = <
				["at0000"] = <
					text = <"Detalhes da Refração">
					description = <"Detalhes da refração ocular para propósitos de medidas e terapêuticos.">
				>
				["at0004"] = <
					text = <"*Power of Sphere(en)">
					description = <"*Correction of the sphere, the base correction upon which cylinder, reading addition and prism may be superimposed.(en)">
				>
				["at0005"] = <
					text = <"*Power of Cylinder(en)">
					description = <"*Correction of the cylinder.(en)">
				>
				["at0006"] = <
					text = <"Eixo do Cilindro">
					description = <"Correção do eixo.">
				>
				["at0007"] = <
					text = <"*Prism Strength(en)">
					description = <"*Strength of the prism.(en)">
				>
				["at0008"] = <
					text = <"*Prism Base Direction(en)">
					description = <"*Prism base direction expressed as a numeric angle or as coded text.(en)">
				>
				["at0009"] = <
					text = <"*Base in(en)">
					description = <"*The prism base is directed inwards.(en)">
				>
				["at0010"] = <
					text = <"*Base out(en)">
					description = <"*The prism base is directed outwards.(en)">
				>
				["at0011"] = <
					text = <"*Base up(en)">
					description = <"*The prism base is directed upwards.(en)">
				>
				["at0012"] = <
					text = <"*Base down(en)">
					description = <"*The prism base is directed downwards.(en)">
				>
				["at0013"] = <
					text = <"*Base oblique(en)">
					description = <"*The prism base is directed obliquely.(en)">
				>
				["at0014"] = <
					text = <"*Reading Addition Power(en)">
					description = <"*The difference in spherical power between distance and near corrections.(en)">
				>
				["at0015"] = <
					text = <"*Intermediate Distance Power(en)">
					description = <"*The intermediate distance power applied to the correction.(en)">
				>
				["at0016"] = <
					text = <"*Interpupillary Distance(en)">
					description = <"*The distance between the center of the pupils of the two eyes.(en)">
				>
			>
		>
		["nb"] = <
			items = <
				["at0000"] = <
					text = <"Refraksjonsdetaljer">
					description = <"Detaljer for okulær refraksjon.">
				>
				["at0004"] = <
					text = <"Sfærisk dioptri">
					description = <"Sfærisk korreksjon">
				>
				["at0005"] = <
					text = <"Sylinder dioptri">
					description = <"Sylinderkorreksjon">
				>
				["at0006"] = <
					text = <"Sylinders akse">
					description = <"Sylinders akse">
				>
				["at0007"] = <
					text = <"Prismedioptri">
					description = <"Prismes styrke">
				>
				["at0008"] = <
					text = <"Prismes baseretning">
					description = <"Prismes baseretning uttrykt som vinkelretning eller kodet tekst">
				>
				["at0009"] = <
					text = <"Base inn">
					description = <"Base mot nasalsiden">
				>
				["at0010"] = <
					text = <"Base ut">
					description = <"Base mot lateralsiden">
				>
				["at0011"] = <
					text = <"Base opp">
					description = <"Prismebasen rettet oppover">
				>
				["at0012"] = <
					text = <"Base ned">
					description = <"Prismebasen rettet nedover">
				>
				["at0013"] = <
					text = <"Base skrå">
					description = <"Basen rettet skrått">
				>
				["at0014"] = <
					text = <"Lesetillegg">
					description = <"Lesetillegg er +tillegg for å flytte fokusplanet til leseavstand">
				>
				["at0015"] = <
					text = <"Mellomdistanse">
					description = <"Refraksjonstillegg for å flytte fokusplanet mellom lesedistanse og uendelig.">
				>
				["at0016"] = <
					text = <"Pupilleavstand">
					description = <"Avstanden mellom pupillene på de to øyne">
				>
			>
		>
	>
	term_bindings = <
		["SNOMED-CT"] = <
			items = <
				["at0004"] = <[SNOMED-CT::251795007]>
				["at0005"] = <[SNOMED-CT::251797004]>
				["at0006"] = <[SNOMED-CT::251799001]>
				["at0007"] = <[SNOMED-CT::251762001]>
				["at0008"] = <[SNOMED-CT::246223004]>
				["at0014"] = <[SNOMED-CT::397282003]>
				["at0015"] = <[SNOMED-CT::251802005]>
				["at0016"] = <[SNOMED-CT::397258008]>
			>
		>
	>